F-Theta 扫描镜头通常用于激光扫描系统,该系统采用两轴振镜扫描指定区域,但不能容忍像平面上的角度。通过在扫描镜头中引入特定量的桶形畸变,F-Theta 扫描镜头成为像激光扫描、打标、雕刻和切割系统等图像平面上需要平坦视场的应用的理想选择。根据应用的要求,这些衍射受限的透镜系统可以针对波长、光斑尺寸和焦距进行优化,并且在整个透镜的视场中畸变保持在 0.25% 以下。
零件编号 | 扫描场 | 输入光束 | 焦点 | 最大限度. 扫描角度 | 线 | M1-M2 | WD | 窗户 | |
EFL (mm) |
|
Ф(1/e2) | Ф(1/e2) | (±deg) | (mm) | (mm) | 直径×Thk | ||
(mm) | (mm) | (μm) | (mm) | ||||||
HYP-1064-50-100Q | 100 | 50x50 | 15 | 13 | 21.3 | M85x1 | 25.6 | 131 | 94x2.5 |
HYP-1064-94-163Q | 163 | 94x94 | 20 | 23 | 24.7 | M85x1 | 26 | 204.8 | 138x2.5 |
HYP-1064-112-163Q | 163 | 112x112 | 10 | 30 | 25 | M85x1 | 12.5 | 203.7 | 120x2.5 |
HYP-1064-170-255Q-D20 | 255 | 170x170 | 20 | 24 | 28 | M85x1 | 25.8 | 319.4 | 150x3 |
HYP-1064-142-277Q | 277 | 142x142 | 15 | 32.5 | 21 | M85x1 | 26 | 347.5 | 96x2.5 |
HYP-1064-215-340Q-D20 | 340 | 215x215 | 20 | 32 | 25 | M85x1 | 27 | 203.8 | 140x3.5 |
HYP-1064-220-460Q-D30 | 460 | 220x220 | 30 | 44 | 25 | M98x1 | 43 | 572.4 | 144x4 |
HYP-1064-280-420Q | 420 | 280x280 | 14 | 60.7 | 27 | M85x1 | 17 | 506.3 | 112x2.5 |
HYP-1064-320-450Q | 450 | 320x320 | 14 | 45 | 25 | M85x1 | 15 | 515.9 | 104x3.9 |
HYP-1064-280-500Q-D30 | 500 | 280x280 | 30 | 34 | 22.9 | M85x1 | 37 | 618.3 | 180x3.5 |
HYP-1064-340-500Q-D20 | 500 | 340x340 | 20 | 14.5 | 26.8 | M85x1 | 26 | 569.8 | 140x3.5 |
HYP-1064-350-640Q | 640 | 350x350 | 10 | 95.7 | 23.6 | M85x1 | 16 | 706.9 | 73x2.5 |
HYP-1064-425-875Q-D20 | 875 | 425x425 | 20 | 93.2 | 19.3 | M85x1 | 26 | 975.2 | 83x2.5 |
Part No. | Scan Field | Input Beam | Focus Spot | Max. Scan Angle | Thread | M1-M2 | WD | Window | |
EFL (mm) |
|
Ф(1/e2) | Ф(1/e2) | (±deg) | (mm) | (mm) | Dia×Thk | ||
(mm) | (mm) | (μm) | (mm) | ||||||
HYP-980-160-260Q-D20 | 260 | 160x160 | 20 | 30 | 23 | M85x1 | 27 | 130 | 138x2.5 |
HYP-980-215-335Q-D20 | 335 | 215x215 | 20 | 35 | 24 | M85x1 | 27 | 200 | 140x3.5 |
HYP-980-280-420Q | 418.5 | 280x280 | 14 | 56.1 | 27.1 | M85x1 | 17 | 497.3 | 112x2.5 |
HYP-980-400-640Q-D20 | 640 | 400x400 | 20 | 64 | 24.5 | M85x1 | 27 | 556 | 128x3.5 |
HYP-980-450-650Q-D30 | 650.0 | 450x450 | 30 | 103 | 25 | M123x1 | 37 | 784.9 | 220x5 |
Part No. | Scan Field | Input Beam | Focus Spot | Max. Scan Angle | Thread | M1-M2 | WD | Window | |
EFL (mm) |
|
Ф(1/e2) | Ф(1/e2) | (±deg) | (mm) | (mm) | Dia×Thk | ||
(mm) | (mm) | (μm) | (mm) | ||||||
HYP-1940-635-60-163 | 163 | 60x60 | 14 | 29 | 25 | M85x1 | 18 | 128.2 | 68x2.5 |
Part No. | Scan Field | Input Beam | Focus Spot | Max. Scan Angle | Thread | M1-M2 | WD | Window | |
EFL (mm) |
|
Ф(1/e2) | Ф(1/e2) | (±deg) | (mm) | (mm) | Dia×Thk | ||
(mm) | (mm) | (μm) | (mm) | ||||||
HYP-1064-635-100-163 | 163 | 100x100 | 12 | 22.5 | 25.5 | M85x1 | 20 | 157.6 | 85x2 |
HYP-1064-635-180-260 | 260 | 180x180 | 15 | 28 | 28.3 | M85x1 | 20 | 261.4 | 123x3 |
HYP-1064-630-150-254B | 254 | 150x150 | 30 | 110 | 25 | M102X1 | 43 | 306.9 | 128x4 |
HYP-1064-532-100-163 | 163 | 100x100 | 12 | 21 | 25 | M85x1 | 14 | 159.7 | 84x2 |
HYP-1064-532-175-254 | 254 | 175x175 | 15 | 25 | 28 | M85x1 | 16 | 262.8 | 120x3 |
Part No. | Scan Field | Input Beam | Focus Spot | Max. Scan Angle | Thread | M1-M2 | WD | Window | |
EFL (mm) |
|
Ф(1/e2) | Ф(1/e2) | (±deg) | (mm) | (mm) | Dia×Thk | ||
(mm) | (mm) | (μm) | (mm) | ||||||
HYP-532-635-100-163 | 163 | 100x100 | 10 | 12.4 | 24.8 | M85x1 | 13 | 121 | 97x2.5 |
Part No. | Scan Field | Input Beam | Focus Spot | Max. Scan Angle | Thread | M1-M2 | WD | Window | |
EFL (mm) |
|
Ф(1/e2) | Ф(1/e2) | (±deg) | (mm) | (mm) | Dia×Thk | ||
(mm) | (mm) | (μm) | (mm) | ||||||
HYP-1030-950-200-400 | 400 | 200x200 | 30 | 26.4 | 20 | M85x1 | 36 | 390.2 | 120x3.5 |
Part No. | Scan Field | Input Beam | Focus Spot | Max. Scan Angle | Thread | M1-M2 | WD | Window | |
EFL (mm) |
|
Ф(1/e2) | Ф(1/e2) | (±deg) | (mm) | (mm) | Dia×Thk | ||
(mm) | (mm) | (μm) | (mm) | ||||||
HYP-355-635-90-170 | 170 | 90x90 | 10 | 14 | 21.5 | M85x1 | 20 | 116.1 | 95x2.5 |
HYP-355-635-110-220 | 220 | 110x110 | 10 | 11.5 | 20.2 | M85x1 | 13 | 166.3 | 90x3 |
HYP-355-635-212-328 | 328 | 212x212 | 6 | 45 | 17.9 | M85x1 | 13 | 265.2 | 104x3 |
Part No. | Scan Field | Input Beam | Focus Spot | Max. Scan Angle | Thread | M1-M2 | WD | Window | |
EFL (mm) |
|
Ф(1/e2) | Ф(1/e2) | (±deg) | (mm) | (mm) | Dia×Thk | ||
(mm) | (mm) | (μm) | (mm) | ||||||
HYP-355-532-90-170 | 170 | 90x90 | 10 | 13.1 | 21.5 | M85x1 | 20 | 125.6 | 95x2.5 |
Part No. | Scan Field | Input Beam | Focus Spot | Max. Scan Angle | Thread | M1-M2 | WD | Window | |
EFL (mm) |
|
Ф(1/e2) | Ф(1/e2) | (±deg) | (mm) | (mm) | Dia×Thk | ||
(mm) | (mm) | (μm) | (mm) | ||||||
HYP-355-405-110-178 | 178 | 110x110 | 10 | 15 | 24.7 | M85x1 | 13 | 92.4 | 106x3 |
除了这些标准设计,我们还可以为您开发完整的系统,使用从激光束整形到激光束扩展和分裂的组件。
F-theta 镜头可以拍摄和形成有限距离物体的图像。提供全玻璃高性能镜头,不同镜头满足A3、A4、条码扫描功能。应用于平板扫描仪和高射仪器设备。该镜头接近衍射极限,畸变小,满足使用要求。
通过移动扫描仪来改变光束的方向。通过对焦镜头的对焦,使运动成为焦平面上的焦点之一。激光扫描可分为物镜前扫描和物镜后扫描。通常要求高的扫描设备是前物镜扫描。
1、扫描物镜属于小孔径成像差分系统,对光学分辨率要求较高。
2.因为是光电器件,所以不仅要调整白光(混合光)的像差,还要考虑R、G、B三个独立波长的像差。
3.校正畸变像差。